181212 and 030101: A/JE95/JE95D.HTM

For this page, see JE95 in English or JG95 in German.
For the previous page, see JE94 in English or JG94 in German.
For the next page, see JE96 in English or JG96 in German.
Back to the main page of this colour series, see ../JE in English or ../JG in German.

For this page without and with MTL code (N and F file) for OL with CIEXYZ data of luminous colours and room luminance reflectances:
Yr=0.00, see JE95A in English and JG95A in German
Yr=2.52 (standard), see JE95B in English and JG95B in German
Yr=5.04, see JE95C in English and JG95C in German
Yr=7.56, see JE95D in English and JG95D in German

Fig. B4 and D4 of chromatic ISO/IEC-test chart 2 and 4
Colour Workflow (CW) by the input operator no. 0(D/I), 1(E/J), 5(F/K)
and different output PS operators and Output Linearisation (OL)


Fig. 1: Output layout without the MTL code in the N File (N = No MTL code in the file), see
D95E00N1.PS / TXT / JPG / PDF


Fig. 2: Output layout uses the MTL code with example "linear direct" CIEXYZ output data
for luminance reflectance Yr=0.00 in the F File (F = MTL code in the File)
which produce "equal" output compared to Fig. 1, see
D95E00F1.PS / TXT / JPG / PDF

Remark: In Fig. 2 the output of the grey series in row 4 and 8 is identical and defined by the same grey
output PS operator used in the MTL code. In Fig. 1 the output of the two grey series in row 4 and 8
may be different, because two different input PS operators are used in the N file.

The file names begin with A, B, C or D for the different room reflections Yr=0.00, 2.52 (standard case), 5.04 and 7.56 which change the luminous colours on the monitor. For the directories with this different files see JE95

Remark: The F files of the tables 1 to 3 include the linearising data for one of the model devices A, B, C, or D (=Linear spaced in CIELAB for the room reflections Yr=0,00, 5,04, 7.06 ). The user may modify the CIEXYZ data in an F file. The standard intention is to produce a linearized monitor output which is equally spaced for an appropriate luminance reflectance. If a user replaces the model CIEXYZ data in the F file by his direct CIEXYZ measurement data then this intention is realized.

Input PS operator no. 0(D/I), 1(E/J), 5(F/K)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 0(D/I), 1(E/J), 5(F/K)
to the
output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
D95E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor D95E00FP.PS / TXT / PDF D95E00FP.DAT
D95E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray D95E01FP.PS / TXT / PDF D95E01FP.DAT
D95E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor D95E02FP.PS / TXT / PDF D95E02FP.DAT
D95E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor D95E03FP.PS / TXT / PDF D95E03FP.DAT
D95E04NP.PS / TXT / PDF   4 lab* setcolor D95E04FP.PS / TXT / PDF D95E04FP.DAT
D95E05NP.PS / TXT / PDF  5 LAB* setcolor D95E05FP.PS / TXT / PDF D95E05FP.DAT
D95E06NP.PS / TXT / PDF  6 000n* setcmykcolor D95E06FP.PS / TXT / PDF D95E06FP.DAT
D95E07NP.PS / TXT / PDF  7 w* setgray D95E07FP.PS / TXT / PDF D95E07FP.DAT

Table 1: For PDF start output with linearising data for one of the model devices A, C, D in File (F); Input PS operator no. 0(D/I), 1(E/J), 5(F/K) in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
* All the files are on www.ps.bam.de.

Input PS operator no. 0(D/I), 1(E/J), 5(F/K)
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 0(D/I), 1(E/J), 5(F/K)
to the
output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
D95E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor D95E00FA.PS / TXT D95E00FA.DAT
D95E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray D95E01FA.PS / TXT D95E01FA.DAT
D95E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor D95E02FA.PS / TXT D95E02FA.DAT
D95E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor D95E03FA.PS / TXT D95E03FA.DAT
D95E04NA.PS / TXT   4 lab* setcolor D95E04FA.PS / TXT D95E04FA.DAT
D95E05NA.PS / TXT  5 LAB* setcolor D95E05FA.PS / TXT D95E05FA.DAT
D95E06NA.PS / TXT  6 000n* setcmykcolor D95E06FA.PS / TXT D95E06FA.DAT
D95E07NA.PS / TXT  7 w* setgray D95E07FA.PS / TXT D95E07FA.DAT

Table 2: For PS start output with linearising data for one of the model devices A, C, D in File (F); Input PS operator no. 0(D/I), 1(E/J), 5(F/K) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files of Table 2 it is intended to produce only a PS output and not a PDF output.

Input PS operator no. 0(D/I), 1(E/J), 5(F/K)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 0(D/I), 1(E/J), 5(F/K)
to the
output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
D95E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor D95E00SP.PS / TXT / PDF *) D95E00SP.DAT
D95E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray D95E01SP.PS / TXT / PDF D95E01SP.DAT
D95E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor D95E02SP.PS / TXT / PDF D95E02SP.DAT
D95E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor D95E03SP.PS / TXT / PDF D95E03SP.DAT
D95E04NP.PS / TXT / PDF   4 lab* setcolor D95E04SP.PS / TXT / PDF D95E04SP.DAT
D95E05NP.PS / TXT / PDF  5 LAB* setcolor D95E05SP.PS / TXT / PDF D95E05SP.DAT
D95E06NP.PS / TXT / PDF  6 000n* setcmykcolor D95E06SP.PS / TXT / PDF D95E06SP.DAT
D95E07NP.PS / TXT / PDF  7 w* setgray D95E07SP.PS / TXT / PDF D95E07SP.DAT

Table 3: For PDF start output with linearising data for one of the model devices A, C, D in Startup (S); Input PS operator no. 0(D/I), 1(E/J), 5(F/K) in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

*) Please transfer e. g. the PDF file D95E00SP.PS with the file D95E00SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output ans the file D95E00FP.PDF of the Table 2. All L..SP files of the Table 3 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder JE95, see
../JE.HTM in English or ../JG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.