181101 and 040801: A/LE09/LE09S.HTM

For this page, see LE09 in English or LG09 in German.
For the previous page, see LE08 in English or LG08 in German.
For the next page, see LE10 in English or LG10 in German.
Back to the main page of this colour series, see ../LE in English or ../LG in German.

BAM-test chart no. LE09 for printer output
16 steps: Chromatic to White and Black; Greys
1 page with 16x14 colours and 14 CIE-test colours

Measurement and CIELAB linearization: Colour Workflow (CW) by the input operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) se different output PS operators and without or with MTL code for Output Linearisation (OL)

Input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device S
in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device S
100 kByte
S09E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor S09E00FP.PS / TXT / PDF S09E00FP.DAT
S09E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray S09E01FP.PS / TXT / PDF S09E01FP.DAT
S09E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor S09E02FP.PS / TXT / PDF S09E02FP.DAT
S09E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor S09E03FP.PS / TXT / PDF S09E03FP.DAT
S09E04NP.PS / TXT / PDF   4 lab* setcolor S09E04FP.PS / TXT / PDF S09E04FP.DAT
S09E05NP.PS / TXT / PDF  5 LAB* setcolor S09E05FP.PS / TXT / PDF S09E05FP.DAT
S09E06NP.PS / TXT / PDF  6 000n* setcmykcolor S09E06FP.PS / TXT / PDF S09E06FP.DAT
S09E07NP.PS / TXT / PDF  7 w* setgray S09E07FP.PS / TXT / PDF S09E07FP.DAT

Table 1: Files for the PDF start and linearised output with linearising data of the device S in the File (F); Input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..) in the NP file and output PS operators no. 0 to 7 in the FP file which are transferred by the PS MTL code.

Remark: The files* of Table 1 serve for a PDF output with linearisation data in the File (F) and not for a PS output.
* Files: L..0x, (S,Q,F,O,T)..00(NP,FP,NA,FA,SP).

Input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..)
and start files

*NA.PS / .TXT
140 / 140 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device S
in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device S
100 kByte
S09E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor S09E00FA.PS / TXT S09E00FA.DAT
S09E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray S09E01FA.PS / TXT S09E01FA.DAT
S09E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor S09E02FA.PS / TXT S09E02FA.DAT
S09E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor S09E03FA.PS / TXT S09E03FA.DAT
S09E04NA.PS / TXT   4 lab* setcolor S09E04FA.PS / TXT S09E04FA.DAT
S09E05NA.PS / TXT  5 LAB* setcolor S09E05FA.PS / TXT S09E05FA.DAT
S09E06NA.PS / TXT  6 000n* setcmykcolor S09E06FA.PS / TXT S09E06FA.DAT
S09E07NA.PS / TXT  7 w* setgray S09E07FA.PS / TXT S09E07FA.DAT

Table 2: Files for the PS start and linearised output with linearising data of the device S in the File (F); Input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: The files* of Table 2 serve for a PS output and not for a PDF output.

Input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device S
in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device S
100 kByte
S09E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor S09E00SP.PS / TXT / PDF *) S09E00SP.DAT
S09E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray S09E01SP.PS / TXT / PDF S09E01SP.DAT
S09E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor S09E02SP.PS / TXT / PDF S09E02SP.DAT
S09E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor S09E03SP.PS / TXT / PDF S09E03SP.DAT
S09E04NP.PS / TXT / PDF   4 lab* setcolor S09E04SP.PS / TXT / PDF S09E04SP.DAT
S09E05NP.PS / TXT / PDF  5 LAB* setcolor S09E05SP.PS / TXT / PDF S09E05SP.DAT
S09E06NP.PS / TXT / PDF  6 000n* setcmykcolor S09E06SP.PS / TXT / PDF S09E06SP.DAT
S09E07NP.PS / TXT / PDF  7 w* setgray S09E07SP.PS / TXT / PDF S09E07SP.DAT

Table 3: Files for a PDF start and linearised output with linearising data of the device S in the Startup (S); Input PS operators no. 5 (LAB*(ORS18) setcolor) and 1 (olv*(ORS18) setrgb..) in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

Remark: The files* of Table 3 serve for a PDF output with linearisation data S09E0xSP.DAT (x=0..7) in the Distiller Startup (S) directory and not for a PS output.

*) Please transfer e. g. the PDF file S09E00SP.PS with the file S09E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output as the file S09E00FP.PDF of the Table 2. All the files S09E0xSP.PS (x=0,7) of the Table 3 are distilled with only the default file Example.ps in the Distiller Startup (S) Directory.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder LE09, see
../LE.HTM in English or ../LG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.