181101 and 040801: A/LE68/LE68.HTM

For this page, see LE68 in English or LG68 in German.
For the previous page, see LE67 in English or LG67 in German.
For the next page, see LE69 in English or LG69 in German.
Back to the main page of this colour series, see ../LE in English or ../LG in German.

BAM-test chart no. LE68 for printer output
Max. and half chroma at gamut boundary; Greys
1 page with 16x14 colours and 14 CIE-test colours

Colour Reproduction, Yield and/or Emission: Colour Workflow (CW) by the input operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(OR different output PS operators and without or with MTL code for Output Linearisation (OL)

The output of the S...FP files is darker compared to the output of the L...FP files. For all the files S...(NP/NA/FP/FA/SP) instead of L...(NP/NA/FP/FA/SP) see LE68S in english or LG68S in german

The output of the Q...FP files is lighter compared to the output of the L...FP files. For all the files Q...(NP/NA/FP/FA/SP) instead of L...(NP/NA/FP/FA/SP) see LE68Q in english or LG68Q in german


Fig. LN1: Output layout of all the L...NP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
L68E00N1.PS / TXT / JPG / PDF


Fig. LF1: Output layout of all the L...FP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
L68E00F1.PS / TXT / JPG / PDF


Fig. SF1: Output layout of all the S...FP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
S68E00F1.PS / TXT / JPG / PDF


Fig. QF1: Output layout of all the Q...FP files with the format A6 (here) and A4 in the following tables no. 1 to 3, see
Q68E00F1.PS / TXT / JPG / PDF

Remark 1: The files* of Tables 1 to 3 may produce more than one page layout shown in Fig. LN1

Remark 2: The files* of Tables 1 to 3 produce the format A4 landscape.

Remark 3: The files* of Tables 1 to 3 include the linearising data for the device L = S and Q for the linearized output on this device L. The output of the FP file for the devices S and Q is darker and lighter compared to the output of the device L.

Input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device L
in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device L
100 kByte
L68E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L68E00FP.PS / TXT / PDF L68E00FP.DAT
L68E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L68E01FP.PS / TXT / PDF L68E01FP.DAT
L68E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L68E02FP.PS / TXT / PDF L68E02FP.DAT
L68E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L68E03FP.PS / TXT / PDF L68E03FP.DAT
L68E04NP.PS / TXT / PDF   4 lab* setcolor L68E04FP.PS / TXT / PDF L68E04FP.DAT
L68E05NP.PS / TXT / PDF  5 LAB* setcolor L68E05FP.PS / TXT / PDF L68E05FP.DAT
L68E06NP.PS / TXT / PDF  6 000n* setcmykcolor L68E06FP.PS / TXT / PDF L68E06FP.DAT
L68E07NP.PS / TXT / PDF  7 w* setgray L68E07FP.PS / TXT / PDF L68E07FP.DAT

Table 1: Files for the PDF start and linearised output with linearising data of the device L in the File (F); Input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..) in the NP file and output PS operators no. 0 to 7 in the FP file which are transferred by the PS MTL code.

Remark: The files* of Table 1 serve for a PDF output with linearisation data in the File (F) and not for a PS output.
* Files: L..0x, (S,Q,F,O,T)..00(NP,FP,NA,FA,SP).

Input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..)
and start files

*NA.PS / .TXT
140 / 140 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device L
in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device L
100 kByte
L68E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor L68E00FA.PS / TXT L68E00FA.DAT
L68E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray L68E01FA.PS / TXT L68E01FA.DAT
L68E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor L68E02FA.PS / TXT L68E02FA.DAT
L68E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor L68E03FA.PS / TXT L68E03FA.DAT
L68E04NA.PS / TXT   4 lab* setcolor L68E04FA.PS / TXT L68E04FA.DAT
L68E05NA.PS / TXT  5 LAB* setcolor L68E05FA.PS / TXT L68E05FA.DAT
L68E06NA.PS / TXT  6 000n* setcmykcolor L68E06FA.PS / TXT L68E06FA.DAT
L68E07NA.PS / TXT  7 w* setgray L68E07FA.PS / TXT L68E07FA.DAT

Table 2: Files for the PS start and linearised output with linearising data of the device L in the File (F); Input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: The files* of Table 2 serve for a PS output and not for a PDF output.

Input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device L
in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device L
100 kByte
L68E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L68E00SP.PS / TXT / PDF *) L68E00SP.DAT
L68E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L68E01SP.PS / TXT / PDF L68E01SP.DAT
L68E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L68E02SP.PS / TXT / PDF L68E02SP.DAT
L68E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L68E03SP.PS / TXT / PDF L68E03SP.DAT
L68E04NP.PS / TXT / PDF   4 lab* setcolor L68E04SP.PS / TXT / PDF L68E04SP.DAT
L68E05NP.PS / TXT / PDF  5 LAB* setcolor L68E05SP.PS / TXT / PDF L68E05SP.DAT
L68E06NP.PS / TXT / PDF  6 000n* setcmykcolor L68E06SP.PS / TXT / PDF L68E06SP.DAT
L68E07NP.PS / TXT / PDF  7 w* setgray L68E07SP.PS / TXT / PDF L68E07SP.DAT

Table 3: Files for a PDF start and linearised output with linearising data of the device L in the Startup (S); Input PS operators no. 5 (LAB*(ORS18) setcolor) and 0 (cmyn*(ORS18) setcmyk..) in the NP file and output PS operators no. 0 to in the in SP file which are transferred by the PS MTL code.

Remark: The files* of Table 3 serve for a PDF output with linearisation data L68E0xSP.DAT (x=0..7) in the Distiller Startup (S) directory and not for a PS output.

*) Please transfer e. g. the PDF file L68E00SP.PS with the file L68E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output as the file L68E00FP.PDF of the Table 2. All the files L68E0xSP.PS (x=0,7) of the Table 3 are distilled with only the default file Example.ps in the Distiller Startup (S) Directory.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder LE68, see
../LE.HTM in English or ../LG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.