181101 and 030601: A/CE80/CE80X.HTM
For this page, see
CE80 in English or
CG80 in German.
For the previous page, see
CE79 in English or
CG79 in German.
For the next page, see
CE81 in English or
CG81 in German.
Back to the main page of this colour series, see
../CE in English or
../CG in German.
This page in German for "yield test" without Output Linearisation (OL) by NP files, see CG80X
Fig. 1: ISO/IEC-test chart of form 1 with image frame, see X80E00NA.EPS / GIF /
PDF
Fig. 2: ISO/IEC-test chart of form 2 without image frame, see
Y80E00NA.EPS / GIF
/ PDF
Fig. 3: Output layout, fonts and colour definitions of the ISO/IEC-test
chart of form 2, see Y80EL0NA.EPS /
GIF / PDF
1. Other related
test charts for the test of yield, emission and reproduction properties
by different forms
There are similar proposed ISO/IEC-test charts for different
tests and for Colour Workflow (CW) by different input and
output PS operators
without and with MFL and MTL code for Output Linearisation
(OL). Each file produces 10 pages of 2 series times 5 pages and
2 or 3 forms.
The MFL code (Measurement,
Lightness Function and Linearisation) includes the CIELAB lightness
L* data of the start output. The Output Linearisation is produced
by one simple function. The result is a linearisation of the CIELAB
lightness L* of the grey scale.
The MTL code (Measurement, Transfer and Linearisation)
includes three dimensional CIELAB data of the start output. The
Output Linearisation is done by a Transfer (T) of the corresponding
device coordinates (000n*, w*, nnn0*, www*) to CIELAB coordinates
LAB*. The output transfer changes from LAB* to coordinates of
one of the output PS operators no. 0 to 3. The result is a linearisation
of the CIELAB lightness L* of the grey scale
see the paper (2 pages, 92 kByte) BAMLIN.PDF
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSA" letter for the test of yield and
test chart no. 3 according to ISO/IEC 15775 for the test of image
reproduction properties
Input operator no. 0: 000n* setcmykcolor, see CE79
Input operator no. 1: w* setgray, see CE80
Input operator no. 2: nnn0* setcmykcolor, see CE81
Input operator no. 3: www* setrgbcolor, see CE82
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the "LSA" letter for the test of yield and
test chart no. 3 according to ISO/IEC 15775 for the test of image
reproduction properties
Input operator no. 0: 000n* setcmykcolor, see BE79
Input operator no. 1: w* setgray, see BE80
Input operator no. 2: nnn0* setcmykcolor, see BE81
Input operator no. 3: www* setrgbcolorr, see BE82
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSA" letter for the test of yield and
x-form test chart according to DIN 33870 for the L* lightness
measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE83
Input operator no. 1: w* setgray, see CE84
Input operator no. 2: nnn0* setcmykcolor, see CE85
Input operator no. 3: www* setrgbcolor, see CE86
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the "LSA" letter for the test of yield and
x-form test chart according to DIN 33870 for the L* lightness
measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE83
Input operator no. 1: w* setgray, see BE84
Input operator no. 2: nnn0* setcmykcolor, see BE85
Input operator no. 3: www* setrgbcolorr, see BE86
Proposals for digital ISO/IEC-test charts
for the tests of yield, emission and reproduction properties
with the "LSB" lettter including more graphics and
a yield reference chart of 5% visual area coverage
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSB" letter with more graphics for
the test of yield and x-form test chart according to DIN 33870
for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE87
Input operator no. 1: w* setgray, see CE88
Input operator no. 2: nnn0* setcmykcolor, see CE89
Input operator no. 3: www* setrgbcolor, see CE90
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the "LSB" letter with more graphics for
the test of yield and x-form test chart according to DIN 33870
for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE87
Input operator no. 1: w* setgray, see BE88
Input operator no. 2: nnn0* setcmykcolor, see BE89
Input operator no. 3: www* setrgbcolorr, see BE90
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form test
chart according to DIN 33870 for the L* lightness measurement
of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE91
Input operator no. 1: w* setgray, see CE92
Input operator no. 2: nnn0* setcmykcolor, see CE93
Input operator no. 3: www* setrgbcolor, see CE94
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form test
chart according to DIN 33870 for the L* lightness measurement
of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE91
Input operator no. 1: w* setgray, see BE92
Input operator no. 2: nnn0* setcmykcolor, see BE93
Input operator no. 3: www* setrgbcolorr, see BE94
Equal
input and output PS operator without and with MFL code
for Output Linearisation (OL) with CIELAB L* data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form
test chart according to DIN 33870 for the L* lightness measurement
and six other test charts for the test of image reproduction
properties
Input operator no. 0: 000n* setcmykcolor, see CE95
Input operator no. 1: w* setgray, see CE96
Input operator no. 2: nnn0* setcmykcolor, see CE97
Input operator no. 3: www* setrgbcolor, see CE98
One
input and different output PS operators no. 0 to 7 without
and with MTL code for Output Linearisation (OL) with CIELAB
data of surface colours
with the reference chart of 5%
visual area coverage for the test of yield and x-form
test chart according to DIN 33870 for the L* lightness measurementx
and six other test charts for the test of image reproduction
properties
Input operator no. 0: 000n* setcmykcolor, see BE95
Input operator no. 1: w* setgray, see BE96
Input operator no. 2: nnn0* setcmykcolor, see BE97
Input operator no. 3: www* setrgbcolorr, see BE98
2. Purpose of the Yield test without and with Output Linearisation
For the purpose see BE80X
-------
For an introduction (archive 2000-2009) to all folders
compared to this folder CE80, see
../CE.HTM in English or
../CG.HTM in German.
For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.
For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.
For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.
back to the main page of the TU web site
../../index.html in English.
The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.