181101 and 030601: A/CE80/CE80X.HTM

For this page, see CE80 in English or CG80 in German.
For the previous page, see CE79 in English or CG79 in German.
For the next page, see CE81 in English or CG81 in German.
Back to the main page of this colour series, see ../CE in English or ../CG in German.

Proposal for digital ISO/IEC-test charts of form 1 to 9 for yield and image reproduction properties according to ISO/IEC/FCD 19752:2003
"Method for the determination of toner cartridge yield for monochromatic electrophotographic printers and multifunctional devices that may contain printer components"
Digital files in file formats PostScript (PS) and Portable Document (PDF),
each file produces 10 (20) pages of 2 series times 5 (10) pages and up to 9 forms

This page in German for "yield test" without Output Linearisation (OL) by NP files, see CG80X


Fig. 1: ISO/IEC-test chart of form 1 with image frame, see X80E00NA.EPS / GIF / PDF


Fig. 2: ISO/IEC-test chart of form 2 without image frame, see Y80E00NA.EPS / GIF / PDF


Fig. 3: Output layout, fonts and colour definitions of the ISO/IEC-test chart of form 2, see Y80EL0NA.EPS / GIF / PDF

 

1. Other related test charts for the test of yield, emission and reproduction properties by different forms
There are similar proposed ISO/IEC-test charts for different tests and for Colour Workflow (CW) by different input and output PS operators
without and with MFL and MTL code for Output Linearisation (OL). Each file produces 10 pages of 2 series times 5 pages and 2 or 3 forms.

The MFL code (Measurement, Lightness Function and Linearisation) includes the CIELAB lightness L* data of the start output. The Output Linearisation is produced by one simple function. The result is a linearisation of the CIELAB lightness L* of the grey scale.
The MTL code (Measurement, Transfer and Linearisation) includes three dimensional CIELAB data of the start output. The Output Linearisation is done by a Transfer (T) of the corresponding device coordinates (000n*, w*, nnn0*, www*) to CIELAB coordinates LAB*. The output transfer changes from LAB* to coordinates of one of the output PS operators no. 0 to 3. The result is a linearisation of the CIELAB lightness L* of the grey scale
see the paper (2 pages, 92 kByte) BAMLIN.PDF

Equal input and output PS operator without and with MFL code for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSA" letter for the test of yield and test chart no. 3 according to ISO/IEC 15775 for the test of image reproduction properties
Input operator no. 0: 000n* setcmykcolor, see CE79
Input operator no. 1: w* setgray, see CE80
Input operator no. 2: nnn0* setcmykcolor, see CE81
Input operator no. 3: www* setrgbcolor, see CE82

One input and different output PS operators no. 0 to 7 without and with MTL code for Output Linearisation (OL) with CIELAB data of surface colours
with the "LSA" letter for the test of yield and test chart no. 3 according to ISO/IEC 15775 for the test of image reproduction properties
Input operator no. 0: 000n* setcmykcolor, see BE79
Input operator no. 1: w* setgray, see BE80
Input operator no. 2: nnn0* setcmykcolor, see BE81
Input operator no. 3: www* setrgbcolorr, see BE82

Equal input and output PS operator without and with MFL code for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSA" letter for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE83
Input operator no. 1: w* setgray, see CE84
Input operator no. 2: nnn0* setcmykcolor, see CE85
Input operator no. 3: www* setrgbcolor, see CE86

One input and different output PS operators no. 0 to 7 without and with MTL code for Output Linearisation (OL) with CIELAB data of surface colours
with the "LSA" letter for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE83
Input operator no. 1: w* setgray, see BE84
Input operator no. 2: nnn0* setcmykcolor, see BE85
Input operator no. 3: www* setrgbcolorr, see BE86

Proposals for digital ISO/IEC-test charts for the tests of yield, emission and reproduction properties
with the "LSB" lettter including more graphics and a yield reference chart of 5% visual area coverage

Equal input and output PS operator without and with MFL code for Output Linearisation (OL) with CIELAB L* data of surface colours
with the "LSB" letter with more graphics for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE87
Input operator no. 1: w* setgray, see CE88
Input operator no. 2: nnn0* setcmykcolor, see CE89
Input operator no. 3: www* setrgbcolor, see CE90

One input and different output PS operators no. 0 to 7 without and with MTL code for Output Linearisation (OL) with CIELAB data of surface colours
with the "LSB" letter with more graphics for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE87
Input operator no. 1: w* setgray, see BE88
Input operator no. 2: nnn0* setcmykcolor, see BE89
Input operator no. 3: www* setrgbcolorr, see BE90

Equal input and output PS operator without and with MFL code for Output Linearisation (OL) with CIELAB L* data of surface colours
with the
reference chart of 5% visual area coverage for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see CE91
Input operator no. 1: w* setgray, see CE92
Input operator no. 2: nnn0* setcmykcolor, see CE93
Input operator no. 3: www* setrgbcolor, see CE94

One input and different output PS operators no. 0 to 7 without and with MTL code for Output Linearisation (OL) with CIELAB data of surface colours
with the
reference chart of 5% visual area coverage for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement of 16 grey steps
Input operator no. 0: 000n* setcmykcolor, see BE91
Input operator no. 1: w* setgray, see BE92
Input operator no. 2: nnn0* setcmykcolor, see BE93
Input operator no. 3: www* setrgbcolorr, see BE94

Equal input and output PS operator without and with MFL code for Output Linearisation (OL) with CIELAB L* data of surface colours
with the
reference chart of 5% visual area coverage for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurement and six other test charts for the test of image reproduction properties
Input operator no. 0: 000n* setcmykcolor, see CE95
Input operator no. 1: w* setgray, see CE96
Input operator no. 2: nnn0* setcmykcolor, see CE97
Input operator no. 3: www* setrgbcolor, see CE98

One input and different output PS operators no. 0 to 7 without and with MTL code for Output Linearisation (OL) with CIELAB data of surface colours
with the
reference chart of 5% visual area coverage for the test of yield and x-form test chart according to DIN 33870 for the L* lightness measurementx and six other test charts for the test of image reproduction properties
Input operator no. 0: 000n* setcmykcolor, see BE95
Input operator no. 1: w* setgray, see BE96
Input operator no. 2: nnn0* setcmykcolor, see BE97
Input operator no. 3: www* setrgbcolorr, see BE98

2. Purpose of the Yield test without and with Output Linearisation

For the purpose see BE80X

-------
For an introduction (archive 2000-2009) to all folders compared to this folder CE80, see
../CE.HTM in English or
../CG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.

back to the main page of the TU web site
../../index.html in English.

The last link may not work, if you have visited directly this archive site. Then go to the main page of one of the two TU web sites in a new window
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.