181101 and 030101: A/CE88/CE88S.HTM
For this page, see
CE88 in English or
CG88 in German.
For the previous page, see
CE87 in English or
CG87 in German.
For the next page, see
CE89 in English or
CG89 in German.
Back to the main page of this colour series, see
../CE in English or
../CG in German.
Remark 1: The files of the tables 1 to 3 include the linearising data for the model device L (L=Linear) and the tables 1 to 3 include the linearising data for the model devices S or Q (S=Square Root, Q=Quadratic) or real printer devices F, O or T for the linearized printer output.
and start files *NP.PS / .TXT /.PDF 140 / 140 / 25 kByte |
Output PS operator parameter i*ptrsc |
No colorimetric transfer from the input PS operator no. 1 to the output PS operator no. 1 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *FP.PS / TXT / PDF 240 / 240 / 25 kByte |
100 kByte |
S88E00NP.PS / TXT / PDF | X=0,1,2,3 | S88E00FP.PS / TXT / PDF | S88E00FP.DAT |
Table 1: For PDF start output with linearising data (L=Linear) in File (F); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.
Remark: With the files* of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
and start files *NA.PS / .TXT 140 / 140 kByte |
Output PS operator parameter i*ptrsc |
No colorimetric transfer from the input PS operator no. 1 to the output PS operator no. 1 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *FA.PS / TXT 240 / 240 kByte |
100 kByte |
S88E00NA.PS / TXT | X=0,1,2,3 | S88E00FA.PS / TXT | S88E00FA.DAT |
Table 2: For PS start output with linearising data (L=Linear) in File (F); Input PS operator no. 1 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.
Remark: With the files* of Table 2 it is intended to produce only a PS output and not a PDF output.
and start files *NP.PS / .TXT /.PDF 140 / 140 / 25 kByte |
Output PS operator parameter i*ptrsc |
No colorimetric transfer from the input PS operator no. 1 to the output PS operator no. 1 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *SP.PS / TXT / PDF 240 / 240 / 25 kByte |
100 kByte |
S88E00NP.PS / TXT / PDF | X=0,1,2,3 | S88E00SP.PS / TXT / PDF | S88E00SP.DAT |
Table 3: For PDF start output with linearising data (L=Linear) in Startup (S); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.
*) Please transfer e. g. the PDF file S88E00SP.PS with the file S88E00SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output ans the file S88E00FP.PDF of the Table 2. All L..SP files of the Table 3 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.
Remark: With the files* of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.
and start files *NP.PS / .TXT /.PDF 140 / 140 / 25 kByte |
Output PS operator parameter i*ptrsc |
No colorimetric transfer from the input PS operator no. 1 to the output PS operator no. 1 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *FP.PS / TXT / PDF 240 / 240 / 25 kByte |
100 kByte |
S88E10NP.PS / TXT / PDF | X=0,1,2,3 | S88E10FP.PS / TXT / PDF | S88E10FP.DAT |
Table 4: For PDF linearized output with linearising data of the device (S, Q, F, O or T) in File (F); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.
Remark: With the files* of Table 4 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
and start files *NA.PS / .TXT 140 / 140 kByte |
Output PS operator parameter i*ptrsc |
No colorimetric transfer from the input PS operator no. 1 to the output PS operator no. 1 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *FA.PS / TXT 240 / 240 kByte |
100 kByte |
S88E10NA.PS / TXT | X=0,1,2,3 | S88E10FA.PS / TXT | S88E10FA.DAT |
Table 5: For PS linearized output with linearising data of the device (S, Q, F, O or T) in File (F); Input PS operator no. 1 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.
Remark: With the files* of Table 5 it is intended to produce only a PS output and not a PDF output.
and start files *NP.PS / .TXT /.PDF 140 / 140 / 25 kByte |
Output PS operator parameter i*ptrsc |
No colorimetric transfer from the input PS operator no. 1 to the output PS operator no. 1 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *SP.PS / TXT / PDF 240 / 240 / 25 kByte |
100 kByte |
S88E10NP.PS / TXT / PDF | X=0,1,2,3 | S88E10SP.PS / TXT / PDF *) | S88E10SP.DAT |
Table 6: For PDF linearized output with linearising data of the device (S, Q, F, O or T) in Startup (S); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.
*) Please transfer e. g. the PDF file S88E10SP.PS with the file S88E10SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output ans the file S88E10FP.PDF of the Table 2. All L..SP files of the Table 3 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.
Remark: With the files* of Table 6 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.
-------
For an introduction (archive 2000-2009) to all folders
compared to this folder CE88, see
../CE.HTM in English or
../CG.HTM in German.
For information (archive 2000-2009) about International and
National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.
For information (archive 2000-2009) about colour test charts
and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.
For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.
Back to the main page of the TU web site
(not archive), see
../../index.html in English or
../../indexDE.html in German.
The last link may not work, if you have visited
directly this archive site.
Then go to the main page of one of the
two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.