BAM-test chart no. LE11 for monitor output
16 steps: Chromatic to White and Black; Greys
1 page with 16x14 colours and 14 CIE-test colours

Measurement and CIELAB linearization: Colour Workflow (CW) by the input operator no. 1 (olv*(TLS00) setrgbcolor) and
different output PS operators and without or with MTL code for Output Linearisation (OL)

Input PS operator no. 1 (olv*(TLS00) setrgbcolor)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operator no. 1 (olv*(TLS00) setrgbcolor)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device Q
in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device Q
100 kByte
Q11E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor Q11E00FP.PS / TXT / PDF Q11E00FP.DAT
Q11E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray Q11E01FP.PS / TXT / PDF Q11E01FP.DAT
Q11E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q11E02FP.PS / TXT / PDF Q11E02FP.DAT
Q11E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor Q11E03FP.PS / TXT / PDF Q11E03FP.DAT
Q11E04NP.PS / TXT / PDF   4 lab* setcolor Q11E04FP.PS / TXT / PDF Q11E04FP.DAT
Q11E05NP.PS / TXT / PDF  5 LAB* setcolor Q11E05FP.PS / TXT / PDF Q11E05FP.DAT
Q11E06NP.PS / TXT / PDF  6 000n* setcmykcolor Q11E06FP.PS / TXT / PDF Q11E06FP.DAT
Q11E07NP.PS / TXT / PDF  7 w* setgray Q11E07FP.PS / TXT / PDF Q11E07FP.DAT

Table 1: Files for the PDF start and linearised output with linearising data of the device Q in the File (F); Input PS operator no. 1 (olv*(TLS00) setrgbcolor) in the NP file and output PS operators no. 0 to 7 in the FP file which are transferred by the PS MTL code.

Remark: The files* of Table 1 serve for a PDF output with linearisation data in the File (F) and not for a PS output.
* Files: L..0x, (S,Q,F,O,T)..00(NP,FP,NA,FA,SP).

Input PS operator no. 1 (olv*(TLS00) setrgbcolor)
and start files

*NA.PS / .TXT
140 / 140 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operator no. 1 (olv*(TLS00) setrgbcolor)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device Q
in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device Q
100 kByte
Q11E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor Q11E00FA.PS / TXT Q11E00FA.DAT
Q11E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray Q11E01FA.PS / TXT Q11E01FA.DAT
Q11E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q11E02FA.PS / TXT Q11E02FA.DAT
Q11E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor Q11E03FA.PS / TXT Q11E03FA.DAT
Q11E04NA.PS / TXT   4 lab* setcolor Q11E04FA.PS / TXT Q11E04FA.DAT
Q11E05NA.PS / TXT  5 LAB* setcolor Q11E05FA.PS / TXT Q11E05FA.DAT
Q11E06NA.PS / TXT  6 000n* setcmykcolor Q11E06FA.PS / TXT Q11E06FA.DAT
Q11E07NA.PS / TXT  7 w* setgray Q11E07FA.PS / TXT Q11E07FA.DAT

Table 2: Files for the PS start and linearised output with linearising data of the device Q in the File (F); Input PS operator no. 1 (olv*(TLS00) setrgbcolor) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: The files* of Table 2 serve for a PS output and not for a PDF output.

Input PS operator no. 1 (olv*(TLS00) setrgbcolor)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operator no. 1 (olv*(TLS00) setrgbcolor)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device Q
in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device Q
100 kByte
Q11E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor Q11E00SP.PS / TXT / PDF *) Q11E00SP.DAT
Q11E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray Q11E01SP.PS / TXT / PDF Q11E01SP.DAT
Q11E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q11E02SP.PS / TXT / PDF Q11E02SP.DAT
Q11E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor Q11E03SP.PS / TXT / PDF Q11E03SP.DAT
Q11E04NP.PS / TXT / PDF   4 lab* setcolor Q11E04SP.PS / TXT / PDF Q11E04SP.DAT
Q11E05NP.PS / TXT / PDF  5 LAB* setcolor Q11E05SP.PS / TXT / PDF Q11E05SP.DAT
Q11E06NP.PS / TXT / PDF  6 000n* setcmykcolor Q11E06SP.PS / TXT / PDF Q11E06SP.DAT
Q11E07NP.PS / TXT / PDF  7 w* setgray Q11E07SP.PS / TXT / PDF Q11E07SP.DAT

Table 3: Files for a PDF start and linearised output with linearising data of the device Q in the Startup (S); Input PS operator no. 1 (olv*(TLS00) setrgbcolor) in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.

Remark: The files* of Table 3 serve for a PDF output with linearisation data Q11E0xSP.DAT (x=0..7) in the Distiller Startup (S) directory and not for a PS output.

*) Please transfer e. g. the PDF file Q11E00SP.PS with the file Q11E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output as the file Q11E00FP.PDF of the Table 2. All the files Q11E0xSP.PS (x=0,7) of the Table 3 are distilled with only the default file Example.ps in the Distiller Startup (S) Directory.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder LE11, see
../LE.HTM in English or ../LG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.