181212 and 030101: A/DE50/DE50.HTM

For this page, see DE50 in English or DG50 in German.
For the previous page, see DE49 in English or DG49 in German.
For the next page, see DE51 in English or DG51 in German.
Back to the main page of this colour series, see ../DE in English or ../DG in German.

Start and linearized printer output of Fig. B4
of the ISO/IEC-test chart no. 2 (offset range) according to ISO/IEC 15775:1999-12

Output Linearisation (OL) in the file is used here.
For more information about OL and the different methods see DE48.HTM

The following output includes two times 64 colours in the top and bottom series

Top series: LAB* data are used in the file NP and the transfer to the cmy* data in the files CP, FP
Bottom series: cmy0* data are used in the files NP, CP, FP

1. No Output Linearization (OLN) and NO LAB*_to_cmy* transfer to produce thus start output (Step S1a)
Remark: Printers L, Q and S are model printers with linear, quadratic ans square root output.
Fig. B3 and B4 of ISO/IEC-test chart no. 2
(N=No Colorimetric Transfer LAB*_to _cmy*,
No Output Linearization)
Format PS and Portable Document Format (Version 3.0), File extention NA.PS, NA.TXT, and NA.PDF Format PS and Portable Document Format (Version 3.0), File extention NP.PS, NP.TXT, and NP.PDF
Printer x=F, PS output method only

F50E00NA .PS / .TXT / PDF
119 / 119 /39 kByte

-
Printer x=O, PS and PDF output method

O50E00NA .PS / .TXT / PDF
119 / 119 /39 kByte

O50E00NP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=T, PS and PDF output method

T50E00NA .PS / .TXT / PDF
119 / 119 /39 kByte

T50E00NP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=L, PS and PDF output method
(L=Linear Measurement Data Table)

L50E00NA .PS / .TXT / PDF
119 / 119 /39 kByte

L50E00NP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=Q, PS and PDF output method
(Q=Quadratic Measurement Data Table)

Q50E00NA .PS / .TXT / PDF
119 / 119 /39 kByte

Q50E00NP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=S, PS and PDF output method
(S=Square root Measurement Data Table)

S50E00NA .PS / .TXT / PDF
119 / 119 /39 kByte 

S50E00NP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Top series: The PostScript operator LAB* setcolor is used.
Bottom series: The PostScript operator cmy0* setcmykcolor is used.
Both series are different and No Output Linearisation (OL) is applied.

2. No Output Linearization (OLN) and LAB*_to_cmy* transfer to produce this start output (Step S1b)
Remark: Printers L, Q and S are model printers with linear, quadratic ans square root output.
Fig. B3 and B4 of ISO/IEC-test chart no. 2
(C=Colorimetric Transfer LAB*_to _cmy*,
No Output Linearization)
Format PS and Portable Document Format (Version 3.0), File extention NA.PS, NA.TXT, and NA.PDF Format PS and Portable Document Format (Version 3.0), File extention NP.PS, NP.TXT, and NP.PDF
Printer x=F, PS output method only

F50E00CA .PS / .TXT / PDF
119 / 119 /39 kByte

-
Printer x=O, PS and PDF output method

O50E00CA .PS / .TXT / PDF
119 / 119 /39 kByte

O50E00CP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=T, PS and PDF output method

T50E00CA .PS / .TXT / PDF
119 / 119 /39 kByte

T50E00CP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=L, PS and PDF output method
(L=Linear Measurement Data Table)

L50E00CA .PS / .TXT / PDF
119 / 119 /39 kByte

L50E00CP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=Q, PS and PDF output method
(Q=Quadratic Measurement Data Table)

Q50E00CA .PS / .TXT / PDF
119 / 119 /39 kByte

Q50E00CP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=S, PS and PDF output method
(S=Square root Measurement Data Table)

S50E00CA .PS / .TXT / PDF
119 / 119 /39 kByte 

S50E00CP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Top series: The PostScript operator LAB* setcolor is transferred by a PS procedure LAB*_to_cmy* to cmy0* setcmykcolor.
Bottom series: The PostScript operator cmy0* setcmykcolor is used.
Both series are identical. No Output Linearisation (OL) is applied.

3. File Output Linearization (OLF) and LAB*_to_cmy* transfer to produce the linearized output (step S2)
Remark: Printers L, Q and S are model printers with linear, quadratic ans square root output.

The actual measurement LAB* CIELAB data for the colours 1 to 128 (see also DE59.HTM) of the file FP.PS, e. g. T50E00FP.PS, must be included in the digital file FP.PS, e. g. T50E00FP.PS, to produce a linearized output of an actual printer.
Fig. B3 and B4 of ISO/IEC-test chart no. 2
(F=Colorimetric Transfer LAB*_to _cmy*
and File Output Linearization)
Format PS and Portable Document Format (Version 3.0), File extention FA.PS, FA.TXT, and FA.PDF Format PS and Portable Document Format (Version 3.0), File extention FP.PS, FP.TXT, and FP.PDF
Printer x=F, PS output method only

F50E00FA .PS / .TXT / PDF
119 / 119 /39 kByte

-
Printer x=O, PS and PDF output method

O50E00FA .PS / .TXT / PDF
119 / 119 /39 kByte

O50E00FP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=T, PS and PDF output method

T50E00FA .PS / .TXT / PDF
119 / 119 /39 kByte

T50E00FP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=L, PS and PDF output method
(L=Linear Measurement Data Table)

L50E00FA .PS / .TXT / PDF
119 / 119 /39 kByte

L50E00FP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=Q, PS and PDF output method
(Q=Quadratic Measurement Data Table)

Q50E00FA .PS / .TXT / PDF
119 / 119 /39 kByte

Q50E00FP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Printer x=S, PS and PDF output method
(S=Square root Measurement Data Table)

S50E00FA .PS / .TXT / PDF
119 / 119 /39 kByte 

S50E00FP .PS / TXT / PDF
119 / 119 / 39 kByt e 
Top series: The PostScript operator LAB* setcolor is transferred by a PS procedure LAB*_to_cmy* to cmy0* setcmykcolor.
Bottom series: The PostScript operator cmy0* setcmykcolor is used.
By application of Output Linearisation (OL) both series have changed (except x=L). Both series are still identical.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder DE50, see
../DE.HTM in English or ../DG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.