Requirements and tests for the preparation of refilled toner modules
for electrophotographical printers, copiers and facsimile machines
The DIN-test charts according to DIN
33870:2001-01
1. with english text: DE02
2. with german text: DG02
Vorschlag
für DIN-Prüfvorlagen für zukünftige Version
von DIN 33870
1. mit deutschem Text mit MTL-Code in Distiller Startup Verzeichnis:
DG22
1.
Version and changes
2002-09-05: New improved version 2.0 of this material. This new
version replaces the older version 1.9 in the directory DE18
1. Test with black areas of 5% area coverage (X form) and seven additonal test pages.
2. Measurement
data in the directory "Copy Adobe Acrobat Distiller/Startup"
for:
Linearisation of the output grey steps and output of the tables
and graphical representation of the results
MTLE00SP.PS
3. It is
recommended to study first the following workflow paper (7 pages,
345 kByte)
D33870E.PDF
Four files are necessary for the test. For download the use of Table 1 (introduction) or Table 2 (professional test) in recommended.
2. Test goal and short
description of the test procedure
Step S1: Start output of 20 pages
with 16 non equidistant grey
steps (X form) on the last page no. 20 for the measurement of
CIE lightnesses L* no. 0 to 31.
Step S2: Linearized output of 10 printer series each of 1/10 of the declared OEM yield, e. g. 10 times 500 pages. Each set of 500 pages include 493 pages with and seven additional test pages with the 16 grey steps (X form) on the last page for the measurement of CIE lightnesses L*
Remark: At the end of the life time of the toner modul the 16 grey steps are not any more equidistant and may be very irregular. This is specified by measurement the CIE lightness differences L* in tables and figures (compare step S3)
Step S3: Produce on different pages two Tables and two Figures for the specification of the reproduction properties (CIELAB lightness differences L*) for the 16 step grey output of e. g. page 500, 1000, ..., 5000 according to Annex G of DIN 33866-1:2000-08 and ISO/IEC 15775:1999-12.
3. introduction: toner
yield test for 20 pages (one series)
Part 3 includes an introduction
in the toner yield test with an output of only 20 pages. The
results are presented in form of two tables and two figures.
This part is not necessary for an advanced user which may skip
directly to part 4.
Part 4 includes the running of the test with an output of e. g. 5000 pages. The results are presented on five pages. Each page includes two tables and two figures.
Example: see 20 example pages of the file L22E00NP.PDF
The following files may be downloaded or the text files (.TXT) may viewed first from Table 1 by a web browser in the web window.
1. The file L22E00NP.PS (N=No STARUP file) is transfered with the software Adobe Acrobat Distiller to a PDF file and printed on a printer as output S1.
2 . The lightnesses L* of the 2 x 16 grey steps of the output S1 (last page no. 20) are measured in the sequence 0 to 31.
3. The 2 x 16 L*-lightness data of the output S1 are included in the file MTLE00SP.PS in the directory "STARTUP" of the Copy of Acrobat Distiller.
4. The file L22E00SP.PS (S=Startup file) is transferred to a PDF file with the Copy of Acrobat Distiller.
Remark: The PDF file
is produced with the L* lightness data of the output S1
in the directory "STARTUP".
Attention: A Restart of the Distiller is necessary if any
data in the "STARTUP" is changed.
5. The output of the file L22E00SP.PDF leads to the intended linearized printer output for the grey steps of the last page no. 20.
6 . The lightnesses L* of the 2 x 16 grey steps of the output S2 (last page no. 20) are measured in the sequence 0 to 31.
7. The 2 x 16 L*-lightness
data of the output S2 are additionally included in the
file MTLE00SP.PS in the directory
"STARTUP" of the Copy of Acrobat Distiller.
Attention: A Restart of the Distiller is necessary if any
data in the "STARTUP" is changed.
Example: see one example page of the file X22E00SP.PDF
8. The file X22E00SP.PS (X=Result) is transferred to a PDF file with the Copy of Acrobat Distiller.
9. The output of the file X22E00SP.PDF includes the results of S1 and S2 in two tables and two figures.
Remark: This output shows the specification of the reproduction properties of the start and linearized output.
Test file for the output of 20 pages and one page of test documentation
Digital DIN-test charts according to DIN 33870:2000-01 |
Remarks for use and reproduction | File with PostScript code and measurement data S1 or S2 necessary | Text and PostScript format File extension P.PS for 16 grey steps and additional test pages |
Step S1: Start output of 16 grey steps on the last page no. 20 | Serves for a first output; Measurement of the non equidistant 16 grey steps on the last page no. 20 necessary |
Use original Distiller with only "Example.PS" in "STARTUP" |
150 kByte |
Step S2: Linearised output of 16 grey steps on the last page no. 20 | Serves for linearized output; Measurement of the16 equidistant grey steps on the last test page no. 20 for the test report |
MTLE00SP.PS 7 kByte |
150 kByte |
Step S3: Specification of the reproduction properties of the start and linearized output | Serves for the comparison of the 16 grey steps of the start and linearised output |
MTLE00SP.PS 7 kByte |
65 kByte |
Remark 1: The files with the extension P.TXT ared used for the reading with a web browser and the files with the extension P.PS are recommended for the download.
Remarks for the files:
There are four identical
PostScript-files (except the file name for identification)
with the file extensions "NP.TXT", "NP.PS"
and "SP.TXT" and "SP.PS" file.
The files with the extentions ".TXT" show directly the PostScript-program code in the browser window.
The files with the extention "P.PS" must be downloaded to the local disk and transfered to a file "P.PDF" by the local software Adobe Acrobat Distiller or an equivalent software.
The results of the tests in Step S2 are independend of the Distiller version as long as all outputs of the steps S1 to S3 are made with the same version of Adobe Acrobat Reader , e. g. version 4.0.
One can use the produced PDF files to show the DIN-test charts according to DIN 33870 on any monitor and on any colour or black and white printer (not only on PS printers) with the software Adobe Acrobat Reader .
4. Running
the toner yield test for e. g. 5000 pages
Note: An advanced user may skip
section 3 and start with this section 4.
This test is divided into10 parts
with 1/10 of the declared OEM toner yield each. For this 10 output
series (scount1=1, scount2=10) are produced with for example 500
pages each (pcount1=1, pcount2=500).
1. In the file L22E00NP.PS the default values scount2=1, pcount2=20 (please search at the beginning of the file) are replaced for example by the data scount2=1 (not 10! here), pcount2=500.
2. The file L22E00NP.PS (N=No STARUP file) is transfered with the original software Adobe Acrobat Distiller to a PDF file and printed as output S1 on a printer.
3 . The lightnesses L* of the 2 x 16 grey steps of the output S1 (e. g. last page no. 500) are measured in the sequence 0 to 31.
4. In the file L22E00SP.PS the default values scount2=1, pcount2=20 (please search at the beginning of the file) are replaced for example by the data scount2=10, pcount2=500.
Example: see 5000 example pages of the file L22E00SP.PDF (11,4 MByte !)
5. The file L22E00SP.PS (S=Measurement data S1 in STARUP file) is transferred
to a PDF file with the Copy of Acrobat Distiller.
Attention: A Restart of the Distiller is necessary if any
data in the "STARTUP" is changed.
Remark: The produced file PDF includes 5000 pages: 10 times 493 pages in X form with 5% black area coverage and 7 additional pages with the 16 equidistant grey steps on pages 500, 1000, 1500, ... 5000.
6. The printer output of the file L22E00SP.PDF in 10 parts (only page 500 to test the equisdistance of the 16 grey steps, pages 501 to 1000, ..., pages 4501 to 5000) serves for the test of the toner yield and of the reproduction properties.
For the documentation of five output series, e. g. of S1 (page 500 of NP file) and S2 (page 500 of FP file), S1 and S22 (page 1000 of FP file), S1 and S27 (page 4000 of FP file), S1 and S28 (page 4500 of FP file), S1 and S29 (page 5000 of FP file) the following steps are necessary:
7. The file MTLE00SY.PS (instead of the file MTLE00SP.PS) is copied into the directory "STARTUP" of the Copy of Acrobat Distiller.
8. The 2 x 16 L*-lightness
data S1 and the 5 x 2 x16 L*-lightness data of the
outputs S21, S22, S27, S28, S29 are included in the file
MTLE00SY.PS.
Note: A Restart of the Distiller is necessary if any data in the
"STARTUP" is changed.
Example: see the 5 pages of the file X22E00SY.PDF
9. The file X22E00SY.PS (X=Result) is transferred to a PDF file with the Copy of Acrobat Distiller.
10. The output of the file X22E00SP.PDF includes the results of S1 and S2, S1 and S22, S1 and S27, S1 and S28, S1 and S29 on five pages by two tables and two figures on every page.
Test file for the output of e. g. 5000 pages and five pages of test documentation
Digital DIN-test charts according to DIN 33870:2000-01 |
Remarks for use and reproduction | Measurement data S1 necessary for Step S2 and measurement data S1 and S2 for Step S3 | Text and PostScript format File extension P.TXT and P.PS |
Step S1: Start output of 16 grey steps on the last page no. 500 | Serves for a first output; Measurement of the non equidistant 16 grey steps on the last page no. 500 necessary |
Use original Distiller with only "Example.PS" in "STARTUP" |
150 kByte |
Step S2: Linearised output of 16 grey steps on the last page no. 500 | Serves for linearized output; Measurement of the16 equidistant grey steps on the test pages no. 500, 1000, ..., 4000, 4500, 5000 for the test report |
MTLE00SY.PS 7 kByte |
150 kByte |
Step S3: Specification of the reproduction properties of the start and e. g. 5 linearized output | Serves for the comparison of the 16 grey steps of the start and linearised output on the test pages no. 500, 1000, ..., 4000, 4500, 5000. |
MTLE00SY.PS 7 kByte |
65 kByte |
The file MTLG00YS.PS is prepared for the presentation of the results of five output series (S1 und S2, S1 und S22, S1 und S27, S1 und S28, S1 und S29) on five pages with twoTables and two Figures on each page.
5.0 Probleme mit Software Adobe Acrobat Distiller 4.0 oder Adobe Acrobat Reader 4.0
Problem DINA4 page Portrait or Landscape:
The software Adobe Acrobat Distiller has a default paper
format, e. g. A4 Portrait or A4 Landscape. This default value
may be seen under
Distiller/default values/preferences/extended
Solution: One may change the width to 842 points (=297 mm) and the high to 595 points (=210 mm) and store the start option, e. g. "PrintOptimized" as "PrintOptimizedL" (L=Landscape). Original and Copy Distiller may work then continuously with this Landscape option and the pages may be shown as intended by the software Adobe Acrobat Reader in the format Landscape. For the output with the Reader it may be necessary to choose again the option "A4 Landscape".
Problem fonts:
Under Windows the software Distiller may produce a failure message
for the four used fonts Times, Times-Bold, etc. There is still
a production of the PDF file. The Distiller has a default value
for the fonts. One can see this default value under
Distiller/default values/preferences/fonts
Solution: Under "Inclusion" the 14 Base (Adobe) fonts may be included or not. One may choose for the four Adobe-Times fonts Inclusion "No". Then there is not any more a failure message during the production of a PDF file.
-------
For an introduction (archive 2000-2009) to all folders
compared to this folder DE22, see
../DE.HTM in English or
../DG.HTM in German.
For information (archive 2000-2009) about International and
National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or
../4STAG.html in German.
For information (archive 2000-2009) about colour test charts
and colorimetric calculations, see
../indexAE.html in English or
../indexAG.html in German.
For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or
../XY91AG.html in German.
Back to the main page of the TU web site
(not archive), see
../../index.html in English or
../../indexDE.html in German.
The last link may not work, if you have visited
directly this archive site.
Then go to the main page of one of the
two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.