BAM-test chart no. LE04 for printer output
16 steps: Chromatic to White and Black; Greys
1 page with 16x14 colours and 14 CIE-test colours

Measurement and CIELAB linearization: Colour Workflow (CW) by the input operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) different output PS operators and without or with MTL code for Output Linearisation (OL)

Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device Q
in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device Q
100 kByte
Q04E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor Q04E00FP.PS / TXT / PDF Q04E00FP.DAT
Q04E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray Q04E01FP.PS / TXT / PDF Q04E01FP.DAT
Q04E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q04E02FP.PS / TXT / PDF Q04E02FP.DAT
Q04E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor Q04E03FP.PS / TXT / PDF Q04E03FP.DAT
Q04E04NP.PS / TXT / PDF   4 lab* setcolor Q04E04FP.PS / TXT / PDF Q04E04FP.DAT
Q04E05NP.PS / TXT / PDF  5 LAB* setcolor Q04E05FP.PS / TXT / PDF Q04E05FP.DAT
Q04E06NP.PS / TXT / PDF  6 000n* setcmykcolor Q04E06FP.PS / TXT / PDF Q04E06FP.DAT
Q04E07NP.PS / TXT / PDF  7 w* setgray Q04E07FP.PS / TXT / PDF Q04E07FP.DAT

Table 1: Files for the PDF start and linearised output with linearising data of the device Q in the File (F); Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..) in the NP file and output PS operators no. 0 to 7 in the FP file which are transferred by the PS MTL code.

Remark: The files* of Table 1 serve for a PDF output with linearisation data in the File (F) and not for a PS output.
* Files: L..0x, (S,Q,F,O,T)..00(NP,FP,NA,FA,SP).

Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..)
and start files

*NA.PS / .TXT
140 / 140 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device Q
in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device Q
100 kByte
Q04E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor Q04E00FA.PS / TXT Q04E00FA.DAT
Q04E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray Q04E01FA.PS / TXT Q04E01FA.DAT
Q04E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q04E02FA.PS / TXT Q04E02FA.DAT
Q04E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor Q04E03FA.PS / TXT Q04E03FA.DAT
Q04E04NA.PS / TXT   4 lab* setcolor Q04E04FA.PS / TXT Q04E04FA.DAT
Q04E05NA.PS / TXT  5 LAB* setcolor Q04E05FA.PS / TXT Q04E05FA.DAT
Q04E06NA.PS / TXT  6 000n* setcmykcolor Q04E06FA.PS / TXT Q04E06FA.DAT
Q04E07NA.PS / TXT  7 w* setgray Q04E07FA.PS / TXT Q04E07FA.DAT

Table 2: Files for the PS start and linearised output with linearising data of the device Q in the File (F); Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: The files* of Table 2 serve for a PS output and not for a PDF output.

Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device Q
in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device Q
100 kByte
Q04E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor Q04E00SP.PS / TXT / PDF *) Q04E00SP.DAT
Q04E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray Q04E01SP.PS / TXT / PDF Q04E01SP.DAT
Q04E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor Q04E02SP.PS / TXT / PDF Q04E02SP.DAT
Q04E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor Q04E03SP.PS / TXT / PDF Q04E03SP.DAT
Q04E04NP.PS / TXT / PDF   4 lab* setcolor Q04E04SP.PS / TXT / PDF Q04E04SP.DAT
Q04E05NP.PS / TXT / PDF  5 LAB* setcolor Q04E05SP.PS / TXT / PDF Q04E05SP.DAT
Q04E06NP.PS / TXT / PDF  6 000n* setcmykcolor Q04E06SP.PS / TXT / PDF Q04E06SP.DAT
Q04E07NP.PS / TXT / PDF  7 w* setgray Q04E07SP.PS / TXT / PDF Q04E07SP.DAT

Table 3: Files for a PDF start and linearised output with linearising data of the device Q in the Startup (S); Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 1 (olv*(ORS18) setrgb..) in the NP file and output PS operators no. 0 to in the in SP file which are transferred by the PS MTL code.

Remark: The files* of Table 3 serve for a PDF output with linearisation data Q04E0xSP.DAT (x=0..7) in the Distiller Startup (S) directory and not for a PS output.

*) Please transfer e. g. the PDF file Q04E00SP.PS with the file Q04E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output as the file Q04E00FP.PDF of the Table 2. All the files Q04E0xSP.PS (x=0,7) of the Table 3 are distilled with only the default file Example.ps in the Distiller Startup (S) Directory.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder LE04, see
../LE.HTM in English or ../LG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.