181101 and 040801: A/LE05/LE05.HTM

For this page, see LE05 in English or LG05 in German.
For the previous page, see LE04 in English or LG04 in German.
For the next page, see LE06 in English or LG06 in German.
Back to the main page of this colour series, see ../LE in English or ../LG in German.

BAM-test chart no. LE05 for printer output
16 steps: Chromatic to White and Black; Greys
1 page with 16x14 colours and 14 CIE-test colours

Measurement and CIELAB linearization: Colour Workflow (CW) by the input operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) different output PS operators and without or with MTL code for Output Linearisation (OL)


Fig. LN1: Output layout of all the L...NP files with the format A5 landscape in the following tables no. 1 to 3, see
L05E00N1.PS / TXT / JPG / PDF


Fig. LF1: Output layout of all the L...FP files with the format A5 landscape in the following table no. 1, see
L05E00F1.PS / TXT / JPG / PDF


Fig. SF1: Output layout of all the S...FP files with the format A5 landscape, see
S05E00F1.PS / TXT / JPG / PDF

The output of the S...FP files is darker compared to the output of the L...FP files. For all the files S...(NP/NA/FP/FA/SP) instead of L...(NP/NA/FP/FA/SP) see LE05S in english or LG05S in german


Fig. QF1: Output layout of all the Q...FP files with the format A5 landscape, see
Q05E00F1.PS / TXT / JPG / PDF

The output of the Q...FP files is darker compared to the output of the L...FP files. For all the files Q...(NP/NA/FP/FA/SP) instead of L...(NP/NA/FP/FA/SP) see LE05Q in english or LG05Q in german

Remark 1: The files* of Tables 1 to 3 may produce more than the three different page layouts shown in Fig. LN1 to Fig. LN3

Remark 2: The files* of Tables 1 to 3 produce the format A4 landscape.

Remark 3: The files* of Tables 1 to 3 include the linearising data for the device L = S and Q for the linearized output on this device L. The output of the FP file for the devices S and Q is darker and lighter compared to the output of the device L.

Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device L
in files *FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device L
100 kByte
L05E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L05E00FP.PS / TXT / PDF L05E00FP.DAT
L05E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L05E01FP.PS / TXT / PDF L05E01FP.DAT
L05E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L05E02FP.PS / TXT / PDF L05E02FP.DAT
L05E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L05E03FP.PS / TXT / PDF L05E03FP.DAT
L05E04NP.PS / TXT / PDF   4 lab* setcolor L05E04FP.PS / TXT / PDF L05E04FP.DAT
L05E05NP.PS / TXT / PDF  5 LAB* setcolor L05E05FP.PS / TXT / PDF L05E05FP.DAT
L05E06NP.PS / TXT / PDF  6 000n* setcmykcolor L05E06FP.PS / TXT / PDF L05E06FP.DAT
L05E07NP.PS / TXT / PDF  7 w* setgray L05E07FP.PS / TXT / PDF L05E07FP.DAT

Table 1: Files for the PDF start and linearised output with linearising data of the device L in the File (F); Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor) in the NP file and output PS operators no. 0 to 7 in the FP file which are transferred by the PS MTL code.

Remark: The files* of Table 1 serve for a PDF output with linearisation data in the File (F) and not for a PS output.
* Files: L..0x, (S,Q,F,O,T)..00(NP,FP,NA,FA,SP).

Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor)
and start files

*NA.PS / .TXT
140 / 140 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation by File (F)
with device CIELAB data
of device L
in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code in File (F)
with device CIELAB data
of device L
100 kByte
L05E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor L05E00FA.PS / TXT L05E00FA.DAT
L05E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray L05E01FA.PS / TXT L05E01FA.DAT
L05E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor L05E02FA.PS / TXT L05E02FA.DAT
L05E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor L05E03FA.PS / TXT L05E03FA.DAT
L05E04NA.PS / TXT   4 lab* setcolor L05E04FA.PS / TXT L05E04FA.DAT
L05E05NA.PS / TXT  5 LAB* setcolor L05E05FA.PS / TXT L05E05FA.DAT
L05E06NA.PS / TXT  6 000n* setcmykcolor L05E06FA.PS / TXT L05E06FA.DAT
L05E07NA.PS / TXT  7 w* setgray L05E07FA.PS / TXT L05E07FA.DAT

Table 2: Files for the PS start and linearised output with linearising data of the device L in the File (F); Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor) in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: The files* of Table 2 serve for a PS output and not for a PDF output.

Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor)
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte

Output
PS operator
parameter
i*ptrsc

Colorimetric transfer from the
input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor)
to the output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with Startup (S)
without device CIELAB data
of device L
in files *SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code for Startup (S)
with device CIELAB data
of device L
100 kByte
L05E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor L05E00SP.PS / TXT / PDF *) L05E00SP.DAT
L05E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray L05E01SP.PS / TXT / PDF L05E01SP.DAT
L05E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor L05E02SP.PS / TXT / PDF L05E02SP.DAT
L05E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor L05E03SP.PS / TXT / PDF L05E03SP.DAT
L05E04NP.PS / TXT / PDF   4 lab* setcolor L05E04SP.PS / TXT / PDF L05E04SP.DAT
L05E05NP.PS / TXT / PDF  5 LAB* setcolor L05E05SP.PS / TXT / PDF L05E05SP.DAT
L05E06NP.PS / TXT / PDF  6 000n* setcmykcolor L05E06SP.PS / TXT / PDF L05E06SP.DAT
L05E07NP.PS / TXT / PDF  7 w* setgray L05E07SP.PS / TXT / PDF L05E07SP.DAT

Table 3: Files for a PDF start and linearised output with linearising data of the device L in the Startup (S); Input PS operators no. 0 (cmyn*(ORS18) setcmyk..) and 5 (LAB*(ORS18) setcolor) in the NP file and output PS operators no. 0 to in the in SP file which are transferred by the PS MTL code.

Remark: The files* of Table 3 serve for a PDF output with linearisation data L05E0xSP.DAT (x=0..7) in the Distiller Startup (S) directory and not for a PS output.

*) Please transfer e. g. the PDF file L05E00SP.PS with the file L05E00SP.DAT in the Distiller Startup (S) Directory, which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output as the file L05E00FP.PDF of the Table 2. All the files L05E0xSP.PS (x=0,7) of the Table 3 are distilled with only the default file Example.ps in the Distiller Startup (S) Directory.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder LE05, see
../LE.HTM in English or ../LG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.