181101 and 040801: A/BE70/BE70.HTM
For this page, see
BE70 in English or
BG70 in German.
For the previous page, see
BE69 in English or
BG69 in German.
For the next page, see
BE71 in English or
BG71 in German.
Back to the main page of this colour series, see
../BE in English or
../BG in German.
Fig. 1: Output layout of all the files in the following tables
1 to 3, see L70E00NA.EPS / GIF / PDF
This page includes files for the
following application:
DIN-test chart no. 2 of DIN 33871, form 3, A4 landscape, Colour Workflow
(CW) and Output Linearisation (OL)
For Output Linearisation (OL) CIELAB data are used in the files.
Table 1 includes the output files of the Portable Document format
(L..NP.PS/TXT/PDF and L..FP.PS/TXT/PDF).
Table 2 includes the output files of the PostScript format (L..NA.PS/TXT
and L..FA.PS/TXT).
Table 3 includes the output files of the Portable Document format
(L..NP.PS/TXT/PDF and L..SP.PS/TXT/PDF).
To indicate the Colour Workflow (CW)
at the output different file names are used. The files have usually
the same PS content
The PS content of the files L..NP.PS, L..NA.PS and L..SP.PS of
the Tables 1 to 3 is identical and includes no MTL code.
The PS content of the files L..FP.PS and L..FA.PS of the Tables
1 and 2 is identical and includes the MTL code L..FP.DAT
or L..FA.DAT in the file (F).
The output of the files L..FP.PDF and L..SP.PDF must be identical if the MTL code L..SP.DAT is stored within the Distiller Startup Directory during distilling of the PS file L..SP.PS. The files L..FP.PDF and L..SP.PDF have been produced by the software Adobe Acrobat DIstiller Version 3.0. In the first case the MTL code is located in the file L..FP.PS and in the second case the MTL code L..FP.DAT = L..SP.DAT is not in the file L..SP.PS but in the Startup (S) directory of the software Adobe Acrobat DIstiller.
and start files *NP.PS / .TXT /.PDF 140 / 140 / 25 kByte |
Output PS operator parameter i*ptrsc |
Colorimetric transfer of the input PS operator no. 0 to the output PS operators no. 0 to 7 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *FP.PS / TXT / PDF 240 / 240 / 25 kByte |
100 kByte |
L70E00NP.PS / TXT / PDF | 0 | cmy0* setcmykcolor and 000n* setcmykcolor | L70E00FP.PS / TXT / PDF | L70E00FP.DAT |
L70E01NP.PS / TXT / PDF | 1 | olv* setrgbcolor and w* setgray | L70E01FP.PS / TXT / PDF | L70E01FP.DAT |
L70E02NP.PS / TXT / PDF | 2 | cmy0* setcmykcolor and nnn0* setcmykcolor | L70E02FP.PS / TXT / PDF | L70E02FP.DAT |
L70E03NP.PS / TXT / PDF | 3 | olv* setrgbcolor and www* setrgbcolor | L70E03FP.PS / TXT / PDF | L70E03FP.DAT |
L70E04NP.PS / TXT / PDF | 4 | lab* setcolor | L70E04FP.PS / TXT / PDF | L70E04FP.DAT |
L70E05NP.PS / TXT / PDF | 5 | LAB* setcolor | L70E05FP.PS / TXT / PDF | L70E05FP.DAT |
L70E06NP.PS / TXT / PDF | 6 | 000n* setcmykcolor | L70E06FP.PS / TXT / PDF | L70E06FP.DAT |
L70E07NP.PS / TXT / PDF | 7 | w* setgray | L70E07FP.PS / TXT / PDF | L70E07FP.DAT |
Table 1: For PDF output with linearising data in File (F); Input PS operator no. 0 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.
Remark: With the files of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
and start files *NA.PS / .TXT 140 / 140 kByte |
Output PS operator parameter i*ptrsc |
Colorimetric transfer of the input PS operator no. 0 to the output PS operators no. 0 to 7 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *FA.PS / TXT 240 / 240 kByte |
100 kByte |
L70E00NA.PS / TXT | 0 | cmy0* setcmykcolor and 000n* setcmykcolor | L70E00FA.PS / TXT | L70E00FA.DAT |
L70E01NA.PS / TXT | 1 | olv* setrgbcolor and w* setgray | L70E01FA.PS / TXT | L70E01FA.DAT |
L70E02NA.PS / TXT | 2 | cmy0* setcmykcolor and nnn0* setcmykcolor | L70E02FA.PS / TXT | L70E02FA.DAT |
L70E03NA.PS / TXT | 3 | olv* setrgbcolor and www* setrgbcolor | L70E03FA.PS / TXT | L70E03FA.DAT |
L70E04NA.PS / TXT | 4 | lab* setcolor | L70E04FA.PS / TXT | L70E04FA.DAT |
L70E05NA.PS / TXT | 5 | LAB* setcolor | L70E05FA.PS / TXT | L70E05FA.DAT |
L70E06NA.PS / TXT | 6 | 000n* setcmykcolor | L70E06FA.PS / TXT | L70E06FA.DAT |
L70E07NA.PS / TXT | 7 | w* setgray | L70E07FA.PS / TXT | L70E07FA.DAT |
Table 2: For PS output with linearising data in File (F); Input PS operator no. 0 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.
Remark: With the files of Table 2 it is intended to produce only a PS output and not a PDF output.
The files of the tables 1 to 3 are available for different devices instead of the model device L=Linear. Every device produces with all NP files the same start output. Only for the model device L=Linear of the table 2 the output of the NP and FP in one row is identical. For devices which produce equal output for corresponding colours the output of all FP files in one collum is identical at least for i*ptrsc=0 to 3.
and start files *NP.PS / .TXT /.PDF 140 / 140 / 25 kByte |
Output PS operator parameter i*ptrsc |
Colorimetric transfer of the input PS operator no. 0 to the output PS operators no. 0 to 7 defined by i*ptrsc |
L=Linear data (no change of scaling of output) in files *SP.PS / TXT / PDF 240 / 240 / 25 kByte |
100 kByte |
L70E00NP.PS / TXT / PDF | 0 | cmy0* setcmykcolor and 000n* setcmykcolor | L70E00SP.PS / TXT / PDF | L70E00SP.DAT |
L70E01NP.PS / TXT / PDF | 1 | olv* setrgbcolor and w* setgray | L70E01SP.PS / TXT / PDF | L70E01SP.DAT |
L70E02NP.PS / TXT / PDF | 2 | cmy0* setcmykcolor and nnn0* setcmykcolor | L70E02SP.PS / TXT / PDF | L70E02SP.DAT |
L70E03NP.PS / TXT / PDF | 3 | olv* setrgbcolor and www* setrgbcolor | L70E03SP.PS / TXT / PDF *) | L70E03SP.DAT |
L70E04NP.PS / TXT / PDF | 4 | lab* setcolor | L70E04SP.PS / TXT / PDF | L70E04SP.DAT |
L70E05NP.PS / TXT / PDF | 5 | LAB* setcolor | L70E05SP.PS / TXT / PDF | L70E05SP.DAT |
L70E06NP.PS / TXT / PDF | 6 | 000n* setcmykcolor | L70E06SP.PS / TXT / PDF | L70E06SP.DAT |
L70E07NP.PS / TXT / PDF | 7 | w* setgray | L70E07SP.PS / TXT / PDF | L70E07SP.DAT |
Table 3: For PDF output with linearising data in Startup (S); Input PS operator no. 0 in the NP file and output PS operators no. 0 to 7 in the in SP file which are transferred by the PS MTL code.
*) Only the PDF file L70E03SP.PS is transferred with the file L70E03SP.DAT which uses the parameter i*ptrsc=3 in the Distiller Startup (S) Directory. The other L..SP files of the Table 3 are distilled with the default file Example.ps in the Distiller Startup (S) Directory.
Remark: With the files of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.
The input PS operator no. 0 and the output PS operators no. 0 to 7 are used in the files.The input PS operator(s) of the NA or NP file are transferred to the output PS operator(s) in the FA, FP or SP file by the PS MTL code.
For further information and discussion of the results in the achromatic case with similar files see DE811
For further information and discussion of the results in the chromatic case with similar files see DE841
Compare the final result in DE811 and DE841. The Colour Workflow (CW) and the Output Linearisation (OL) of the PS MTL code is based on ISO/IEC 15775 and DIS ISO/IEC 19839-X. The PS MTL code is compatible to CIELAB and fulfils the basic user requirements in the field of image technology. The result is the same in the achromatic and chromatic case.
------
The ISO/IEC-test charts according to ISO/IEC 15775 and DIS ISO/IEC
19839-1 to -4 with english text: IE13
The ISO/IEC-test charts according to ISO/IEC 15775 and DIS
ISO/IEC 19839-1 to -4 with german text: IG13
The DIN-test charts according to DIN 33866-1 to -5 with german
text: DG13
The DIN-test charts according to DIN 33866-1 to -5 with english
text: DE13
Digital Asian ISO/IEC-test charts with english text: http://www.jbmia.or.jp/~isoiec/sc28/testchart/index.htm
change to DE
(information about DIN 33866-1 to 5: 2000-07 in english)
change to DG (information about DIN 33866-1
to 5: 2000-07 in german)
change to IE (information about ISO/IEC
15775: 1999-12 and DIS ISO/IEC 19839-1 to 4: 2000-04 in english)
change to IG (information about ISO/IEC
15775: 1999-12 and DIS ISO/IEC 19839-1 to 4: 2000-04 in german)
go to DE.HTM
go to home page