181212 and 030101: A/KE87/KE87.HTM

For this page, see KE87 in English or KG87 in German.
For the previous page, see KE86 in English or KG86 in German.
For the next page, see KE88 in English or KG88 in German.
Back to the main page of this colour series, see ../KE in English or ../KG in German.

For this page without and with MTL code for OL with:
CIEXYZ data of luminous colours, see KE87 in English and KG87 in German,
CIELAB data of surface colours, see DE87 in English and DG87 in German.

For this page without and with MTL code (N and F file) for OL with CIEXYZ data of luminous colours and room luminance reflectances:
Yr=0.00, see KE87A in English and KG87A in German
Yr=2.52 (standard), see KE87B in English and KG87B in German
Yr=5.04, see KE87C in English and KG87C in German
Yr=7.56, see KE87D in English and KG87D in German

For colours defined by the input PS operators:
cmyn* setcmykcolor, see IE87 in English and IG87 in German,
olv* setrgbcolor, see JE87 in English and JG87 in German,
LAB* setcolor, see KE87 in English and KG87 in German.

Achromatic ISO/IEC-test chart 3, w* input
Colour Workflow (CW) by the input operator no. 1
and different output PS operators and Output Linearisation (OL)


Fig. 1: Output layout without the MTL code in the N File (N = No MTL code in the file), see
A87E00N1.PS / TXT / JPG / PDF


Fig. 2: Output layout uses the MTL code with example "linear direct" CIEXYZ output data
for luminance reflectance Yr=0.00 in the F File (F = MTL code in the File)
which produce "equal" output compared to Fig. 1, see
A87E00F1.PS / TXT / JPG / PDF


Fig. 3: Output layout uses the MTL code with example "linear direct" CIEXYZ output data
for luminance reflectance Yr=2.52 in the F File (F = MTL code in the File)
which produce "equal" output compared to Fig. 1, see
B87E00F1.PS / TXT / JPG / PDF

Remark: In Fig. 3 the CIEXYZ data which are measured on the surface of the monitor screen are different
compared to Fig. 2. The luminance reflectance Yr=2.52 is added by the PostScript code. This produces
colour scales which are equally spaced in CIELAB, e. g. between L*n=18 and L*w=87 for this office condition.


Fig. 4: Output layout uses the MTL code with example "linear direct" CIEXYZ output data
for luminance reflectance Yr=5.04 in the F File (F = MTL code in the File)
which produce "equal" output compared to Fig. 1, see
C87E00F1.PS / TXT / JPG / PDF

Remark: In Fig. 4 the CIEXYZ data which are measured on the surface of the monitor screen are different
compared to Fig. 2 and Fig. 3. The luminance reflectance Yr=5.04 is added by the PostScript code. This produces
colour scales which are equally spaced in CIELAB, e. g. between L*n=27 and L*w=87 for this office condition.


Fig. 5: Output layout uses the MTL code with example "linear direct" CIEXYZ output data
for luminance reflectance Yr=7.56 in the F File (F = MTL code in the File)
which produce "equal" output compared to Fig. 1, see
D87E00F1.PS / TXT / JPG / PDF

Remark: In Fig. 5 the CIEXYZ data which are measured on the surface of the monitor screen are different
compared to Fig. 2 to Fig. 4. The luminance reflectance Yr=7.56 is added by the PostScript code. This produces
colour scales which are equally spaced in CIELAB, e. g. between L*n=33 and L*w=86 for this office condition.

For information about the parameter i*ptrsc (number 0 to 7) used for input or output PS operators, see IE802

For information about the ISO/IEC-test charts and separate parts (Fig. XY) with different input PS operators and discussion, see IE801

This page includes files for the following application:
Achromatic ISO/IEC-test chart 3, w* input,
Colour Workflow (CW) and Output Linearisation (OL)

For Output Linearisation (OL) CIELAB data are used in the files.

Table 1 includes the output files of the Portable Document format (B..NP.PS/TXT/PDF and B..FP.PS/TXT/PDF)
Table 2 includes the output files of the PostScript format (B..NA.PS/TXT and B..FA.PS/TXT).
Table 3 includes the output files of the Portable Document format (B..NP.PS/TXT/PDF and B..SP.PS/TXT/PDF).

To indicate the Colour Workflow (CW) at the output different file names are used. The files have usually the same PS content

The PS content of the files B..NP.PS, B..NA.PS and B..SP.PS of the Tables 1 to 3 is identical and includes no MTL code.
The PS content of the files B..FP.PS and B..FA.PS of the Tables 1 and 2 is identical and includes the MTL code LB.FP.DAT or B..FA.DAT in the file (F).

The output of the files B..FP.PDF and B..SP.PDF must be identical if the MTL code B..SP.DAT is stored within the Distiller Startup Directory during distilling of the PS file B..SP.PS. The files B..FP.PDF and B..SP.PDF have been produced by the software Adobe Acrobat DIstiller Version 3.0. In the first case the MTL code is located in the file B..FP.PS and in the second case the MTL code B..FP.DAT = B..SP.DAT is not in the file B..SP.PS but in the Startup (S) directory of the software Adobe Acrobat DIstiller.

Input PS operator no. 1
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 1
to the
output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*FP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
B87E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor B87E00FP.PS / TXT / PDF B87E00FP.DAT
B87E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray B87E01FP.PS / TXT / PDF B87E01FP.DAT
B87E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor B87E02FP.PS / TXT / PDF B87E02FP.DAT
B87E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor B87E03FP.PS / TXT / PDF B87E03FP.DAT
B87E04NP.PS / TXT / PDF   4 lab* setcolor B87E04FP.PS / TXT / PDF B87E04FP.DAT
B87E05NP.PS / TXT / PDF  5 LAB* setcolor B87E05FP.PS / TXT / PDF B87E05FP.DAT
B87E06NP.PS / TXT / PDF  6 000n* setcmykcolor B87E06FP.PS / TXT / PDF B87E06FP.DAT
B87E07NP.PS / TXT / PDF  7 w* setgray B87E07FP.PS / TXT / PDF B87E07FP.DAT

Table 1: For PDF output with linearising data for the model device B; Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

Remark: With the files* of Table 1 it is intended to produce only a PDF output with linearisation data in the File (F) and not a PS output.
* All the files are on the www server.

Input PS operator no. 1
and start files

*NA.PS / .TXT
140 / 140 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 1
to the
output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files *FA.PS / TXT
240 / 240 kByte

PostScript MTL code used for output
100 kByte
B87E00NA.PS / TXT  0 cmy0* setcmykcolor and 000n* setcmykcolor B87E00FA.PS / TXT B87E00FA.DAT
B87E01NA.PS / TXT  1 olv* setrgbcolor and w* setgray B87E01FA.PS / TXT B87E01FA.DAT
B87E02NA.PS / TXT  2 cmy0* setcmykcolor and nnn0* setcmykcolor B87E02FA.PS / TXT B87E02FA.DAT
B87E03NA.PS / TXT  3 olv* setrgbcolor and www* setrgbcolor B87E03FA.PS / TXT B87E03FA.DAT
B87E04NA.PS / TXT   4 lab* setcolor B87E04FA.PS / TXT B87E04FA.DAT
B87E05NA.PS / TXT  5 LAB* setcolor B87E05FA.PS / TXT B87E05FA.DAT
B87E06NA.PS / TXT  6 000n* setcmykcolor B87E06FA.PS / TXT B87E06FA.DAT
B87E07NA.PS / TXT  7 w* setgray B87E07FA.PS / TXT B87E07FA.DAT

Table 2: For PS start output with linearising data for the model device B in File (F); Input PS operator no. 1 in the NA file and output PS operators no. 0 to 7 in the in FA file which are transferred by the PS MTL code.

Remark: With the files* of Table 2 it is intended to produce only a PS output and not a PDF output.

The files of the tables 1 to 3 are available additionally for three different room reflexions Yr=0.00, 5.04, and 7.56 instead of the standard room reflection Yr=2.52. Every device produces with all NP files the same start output. For the standard room reflexion Yr=2.52 of the table 2 the output of the NP and FP in one row is identical. For devices which produce equal output for corresponding colours the output of all FP files in one collum is identical.

In application the output of the NP files for different output parameters i*ptrsc is in one collum often different. The output of the FP file of the linearized output devices A, C, and D is different compared to the output of the NP file. The PS MTL code uses the measurement data of up to 256 colours of the start output, see the CIEXYZ data at the beginning of the FP files, for the change and the linearisation of the output.

Input PS operator no. 1
and start files

*NP.PS / .TXT /.PDF
140 / 140 / 25 kByte
Output
PS operator
parameter
i*ptrsc
Colorimetric transfer from the
input PS operator no. 1
to the
output PS operators no. 0 to 7
defined by i*ptrsc

Output Linearisation with
L=Linear data (no change of scaling of output) in files
*SP.PS / TXT / PDF
240 / 240 / 25 kByte

PostScript MTL code used for output
100 kByte
B87E00NP.PS / TXT / PDF  0 cmy0* setcmykcolor and 000n* setcmykcolor B87E00SP.PS / TXT / PDF *) B87E00SP.DAT
B87E01NP.PS / TXT / PDF  1 olv* setrgbcolor and w* setgray B87E01SP.PS / TXT / PDF B87E01SP.DAT
B87E02NP.PS / TXT / PDF  2 cmy0* setcmykcolor and nnn0* setcmykcolor B87E02SP.PS / TXT / PDF B87E02SP.DAT
B87E03NP.PS / TXT / PDF  3 olv* setrgbcolor and www* setrgbcolor B87E03SP.PS / TXT / PDF B87E03SP.DAT
B87E04NP.PS / TXT / PDF   4 lab* setcolor B87E04SP.PS / TXT / PDF B87E04SP.DAT
B87E05NP.PS / TXT / PDF  5 LAB* setcolor B87E05SP.PS / TXT / PDF B87E05SP.DAT
B87E06NP.PS / TXT / PDF  6 000n* setcmykcolor B87E06SP.PS / TXT / PDF B87E06SP.DAT
B87E07NP.PS / TXT / PDF  7 w* setgray B87E07SP.PS / TXT / PDF B87E07SP.DAT

Table 3: For PDF output with linearising data for the model device B in Startup (S); Input PS operator no. 1 in the NP file and output PS operators no. 0 to 7 in the in FP file which are transferred by the PS MTL code.

*) Please transfer e. g. the PDF file B87E00SP.PS with the file B87E00SP.DAT in the Distiller Startup (S) Directory,which uses the parameter i*ptrsc=0. Then this PDF-file produces the same output ans the file B87E00FP.PDF of the Table 2. All L..SP files of the Table 3 are distilled here with only the default file Example.ps in the Distiller Startup (S) Directory.

Remark: With the files* of Table 3 it is intended to produce only a PDF output with linearisation data in the Distiller Startup (S) Directory and not a PS output.

The input operator no. 1 and eight output PS operators no. 0 to 7 are used in the files. The input PS operator no. 1 of the NA or NP file are transferred to the output PS operators no. 0 to 7 in the FA, FP or SP file by the PS MTL code.

For further information and discussion of the results in the achromatic case with similar files see IE811

For further information and discussion of the results in the chromatic case with similar files see IE841

Compare the final result in IE811 and IE841. The Colour Workflow (CW) and the Output Linearisation (OL) of the PS MTL code is based on ISO/IEC 15775 and DIS ISO/IEC 19839-X. The PS MTL code is compatible to CIELAB and fulfils the basic user requirements in the field of image technology. The result is the same in the achromatic and chromatic case.

-------
For an introduction (archive 2000-2009) to all folders compared to this folder KE87, see
../KE.HTM in English or ../KG.HTM in German.

For information (archive 2000-2009) about International and National Standards, Technical Reports, and Meetings, see
../4STAE.html in English or ../4STAG.html in German.

For information (archive 2000-2009) about colour test charts and colorimetric calculations, see
../indexAE.html in English or ../indexAG.html in German.

For publications (archive 2000-2009) of the BAM research group, see
../XY91AE.html in English or ../XY91AG.html in German.

Back to the main page of the TU web site (not archive), see
../../index.html in English or ../../indexDE.html in German.

The last link may not work, if you have visited directly this archive site.
Then go to the main page of one of the two TU web sites in a new window, see
http://farbe.li.tu-berlin.de/index.html or
http://130.149.60.45/~farbmetrik/index.html.